London coverage — Zones 1–6 Same-week appointments Pendulum · Surface Roughness
BS 7976 / HSE Guidance
London — Slip Resistance Testing

Does your floor actually meet the standard?Pendulum testing to BS 7976 across Greater London.

London's dedicated slip resistance testing service. We carry out in-situ pendulum testing and surface roughness (Rz) assessments on commercial, retail, hospitality, healthcare and public sector floors — providing the Pendulum Test Values and written reports you need to evidence compliance, respond to incidents, or verify a new installation.

36+
PTV for low slip potential
5 days
Typical report turnaround
30 areas
Dedicated London coverage
BS 7976-2:2002+A1:2013HSE Slip Assessment ToolUKSRG GuidelinesSurface Roughness — RzForensic ReportsIn-Situ PendulumBS 7976-2:2002+A1:2013HSE Slip Assessment ToolUKSRG GuidelinesSurface Roughness — RzForensic ReportsIn-Situ Pendulum

Two measurements. One authoritative report.

01 / Pendulum

Pendulum Test

BS 7976 · HSE Preferred Method

The pendulum friction tester is the method recognised by the HSE, UKSRG and UK courts for assessing slip potential on hard floors. We record Pendulum Test Values (PTV) in both dry and wet (contaminated) conditions, with full photographic evidence, across every London postcode.

  • PTV readings (dry + wet)
  • Multiple test zones per area
  • 4S and TRL rubber sliders
  • Written report + raw data tables
  • Photography + zone references

Pendulum testing, in depth →

02 / Roughness

Surface Roughness (Rz)

Rz Micro-roughness · Supplementary

Surface micro-roughness (Rz) correlates strongly with wet pendulum performance. We use a portable surface roughness meter to record Rz values across test areas — a useful supplement to pendulum data and particularly valuable when investigating wear patterns on polished stone, resin and tiled floors.

  • Rz readings in µm
  • Zoned mapping across test areas
  • Wear and cleaning-regime assessment
  • Direct correlation with wet PTV
  • Included alongside pendulum reports

Post-incident testing →

From brief to report in five working days.

01

Scope

We agree test areas, access arrangements and report format. Most London jobs are scoped within 24 hours of enquiry.

02

Survey

On-site pendulum or roughness testing, typically 1–3 hours. All readings photographed and logged with location references.

03

Analysis

Readings compared against BS 7976 and HSE slip risk categories. Roughness cross-referenced where recorded.

04

Report

Written report with PTV tables, photography, zone plans and plain-English recommendations — usually issued within 5 working days.

What the numbers actually mean.

PTV 0 – 24
High

High slip potential

1 in 20 chance of a slip or greater. Floor fails to meet the recognised threshold and is likely to produce a claim in wet or contaminated conditions.

PTV 25 – 35
Mod.

Moderate slip potential

1 in 10,000 to 1 in 20. Borderline — management controls, cleaning regime and contamination must be carefully reviewed.

PTV 36+
Low

Low slip potential

Better than 1 in 1,000,000 chance of a slip. The floor is considered to meet the recognised UK standard for slip resistance.

London clients we regularly work with.

Retail & Shopping Centres

Entrance matting, polished stone, escalator landings, food court tiling — high footfall surfaces with changing contamination.

Hospitality & Leisure

Hotel lobbies, bar areas, pool surrounds, kitchens and back-of-house. Wet and contaminated testing to match real use.

Transport & Public Realm

Stations, platforms, passenger terminals, bus depots and external public spaces across London boroughs.

Healthcare & Education

Hospitals, surgeries, schools and universities. Duty-of-care evidence and compliance testing on corridors, wet rooms and labs.

Commercial Offices

Reception areas, entrance lobbies, canteens and tea points. Typical PTV investigations for occupier and landlord disputes.

Residential & Housing

Communal stairs, lobbies, external walkways and paving for housing providers, managing agents and RMCs.

Insurance & Legal

Independent testing for claimant and defendant instructions, including rapid-response site visits following incidents.

Specification & New-Build

In-situ pendulum verification for architects, fit-out contractors and flooring specifiers — confirming finished floors meet the specified slip-resistance performance.

Slip testing across every corner of London.

Dedicated landing pages for the London locations where we do the most work. Each page covers the local context — typical building types, footfall patterns and common test zones — along with our full service and method information.

W1 · Central London
Slip testing in Mayfair
W1 · Central London
Slip testing in Soho
WC2 · Central London
Slip testing in Covent Garden
W8 · West London
Slip testing in Kensington
SW3 · West London
Slip testing in Chelsea
W11 · West London
Slip testing in Notting Hill
W2 · Central London
Slip testing in Paddington
W1 · Central London
Slip testing in Marylebone
NW1 · North London
Slip testing in Camden
N1 · North London
Slip testing in Islington
E8 · East London
Slip testing in Hackney
N5 · North London
Slip testing in Highbury
N1C · Central London
Slip testing in King's Cross
SW15 · South West London
Slip testing in Putney
SW18 · South West London
Slip testing in Wandsworth
SW4 · South London
Slip testing in Clapham
SW9 · South London
Slip testing in Brixton
SW11 · South West London
Slip testing in Battersea
SE10 · South East London
Slip testing in Greenwich
SE1 · South East London
Slip testing in Bermondsey
SE21 · South East London
Slip testing in Dulwich
TW9 · South West London
Slip testing in Richmond
SW19 · South West London
Slip testing in Wimbledon
SW6 · West London
Slip testing in Fulham
EC2A · East London
Slip testing in Shoreditch
E14 · East London
Slip testing in Canary Wharf
E15 · East London
Slip testing in Stratford
E1 · East London
Slip testing in Whitechapel
NW3 · North London
Slip testing in Hampstead
CR0 · South London
Slip testing in Croydon

Questions London clients always ask.

How much does slip testing cost in London?

Pendulum slip testing in London typically ranges from £450 for a single-location survey to £1,200+ for multi-site or multi-area assessments. Costs depend on the number of test areas, accessibility, whether out-of-hours access is required, and report format. Every quote is fixed, written, and includes the on-site work, report and photography.

What is the Pendulum Test Value (PTV)?

The Pendulum Test Value is the measurement produced by a pendulum friction tester under BS 7976. It is an index, not a unit. A PTV of 36 or above indicates a low slip potential, 25–35 moderate, and below 25 high. The HSE recognises pendulum testing as the method for assessing slip risk in the UK. Readings are taken in both dry and contaminated (wet) conditions to reflect real use.

How long does a London slip testing survey take?

A typical single-location pendulum survey in London takes 1–3 hours on site. Larger sites or multi-zone surveys may take longer. A written report with PTV readings, photographs, zone references and recommendations is usually issued within 5 working days. Faster turnaround is available for urgent incident response.

Do I need slip testing after an accident?

Slip testing is commonly instructed following a slip or fall incident, either by the occupier's insurer, the defendant's solicitor or the claimant's solicitor. Independent pendulum readings establish whether the floor met the recognised slip-resistance threshold at the time of testing, which is central to liability. Where possible, test as soon as practical — before cleaning regimes change or the floor is replaced.

Can you test floors without disrupting trading hours?

Yes. Out-of-hours testing is standard for retail, hospitality, transport and healthcare clients. We routinely work evenings, nights and weekends across London. Pendulum testing is non-destructive and leaves no residue beyond the water used for wet readings.

Why are wet pendulum readings more important than dry?

Most real-world slips occur when a floor is wet or contaminated — spilt drinks, tracked-in rainwater, cleaning residue or grease. A floor can score a perfectly strong PTV dry and drop into high or moderate slip potential once water is introduced. Wet pendulum readings reflect real use and are usually the metric that matters for both compliance and litigation.

Book a London slip testing survey.

Tell us the site, the floor, and roughly when you need the report by. We will come back within one working day with a fixed, written quote.

  • ScopingWithin 24h
  • SurveySame week
  • Report5 working days
  • CoverageAll of London

If the form doesn't load, email us directly from the address in your site footer — we'll pick it up the same day.